fixing the low volume issue, finally
This commit is contained in:
@@ -1826,11 +1826,14 @@ function simulateRowState(ptnDat, uptoRow) {
|
||||
const isGRow = (effop === OP_G)
|
||||
const isNoteDelay = (effop === OP_S) && (((effarg >>> 12) & 0xF) === 0xD)
|
||||
// Track whether this row reloads the channel's default volume. Engine:
|
||||
// triggerNote() resets channelVolume to 0x3F only when the row carries an
|
||||
// instrument byte; a note-only retrigger (inst === 0) inherits the
|
||||
// channel's existing volume. Tone-porta rows follow the same rule —
|
||||
// an instrument byte on a porta row reloads default vol (matches
|
||||
// schism csf_instrument_change inst_column branch).
|
||||
// triggerNote() (and the tone-porta-with-inst branch in advanceRow)
|
||||
// seed channelVolume from the instrument's Default Note Volume (byte
|
||||
// 196) — only when the row carries an instrument byte; a note-only
|
||||
// retrigger (inst === 0) inherits the channel's existing volume.
|
||||
// Tone-porta rows follow the same rule (matches schism
|
||||
// csf_instrument_change inst_column branch, effects.c:1302).
|
||||
// The simulator approximates the seed as 0x3F (legacy fallback) — see
|
||||
// the longer note below the reload block for the limitation.
|
||||
let reloadDefaultVol = false
|
||||
if (note !== 0xFFFF && note !== 0xFFFE) {
|
||||
if (note === 0x0000) {
|
||||
@@ -1858,7 +1861,12 @@ function simulateRowState(ptnDat, uptoRow) {
|
||||
// Pan: simulator does not track per-instrument default pan, so it never resets
|
||||
// panAbs on trigger — this naturally matches the "stay at old value when inst === 0"
|
||||
// half of the policy. The engine-side default-pan reload (gated on inst !== 0)
|
||||
// is invisible here.
|
||||
// is invisible here. Same limitation now applies to default volume: the engine
|
||||
// seeds rowVolume from the instrument's byte-196 "Default Note Volume" since
|
||||
// 2026-05-09 (terranmon §171, §196), but the simulator has no instrument-byte
|
||||
// access, so it falls back to 0x3F — equivalent to the legacy "DNV unset"
|
||||
// path. Tracker UI displays may therefore show a slightly off row volume on
|
||||
// fresh triggers when the instrument carries a reduced DNV.
|
||||
if (reloadDefaultVol) volAbs = 0x3F
|
||||
|
||||